Erasing The Dtc Memory; Troubleshooting Intermittent Failures - Honda Civic 2002-2003 Service Manual

Table of Contents

Advertisement

SRS
General Troubleshooting Information (cont'd)
Erasing the DTe Memory
Special Tool Required
SCS service connector 07PAZ-0010l00
To erase the OTC(s) from the SRS unit, use a Honda
PGM Tester (see the Honda PGM Tester SRS Vehicle
System Supplement) or the following procedure.
1. Make sure the ignition switch is OFF.
2. Connect the SCS service connector (A) to the MES
2P connector (B).
00
not use a jumper wire.
3. Turn the ignition switch ON (II).
B
A
07PAZ-0010l00
4. The SRS indicator will come on for about 6 seconds,
and then go off. Remove the SCS service connector
from the MES connector within 4 seconds after the
indicator goes off.
5. The SRS indicator will come on again. Reconnect
the SCS service connector to the MES connector
within 4 seconds after the indicator comes on.
6. When the SRS indicator goes off, remove the SCS
service connector from the MES connector within 4
seconds.
7. The SRS indicator will blink two times indicating
that the memory has been erased.
8. Turn the ignition switch OFF, and wait for 10
seconds.
9. Turn the ignition switch ON (II) again. The SRS is
OK if the SRS indicator comes on for 6 seconds and
then goes off.
23-26
Troubleshooting Intermittent Failures
If there was a malfunction, but it doesn't recur, it will be
stored in the memory as an intermittent failure, and the
SRS indicator will come on.
After checking the OTC, troubleshoot as follows:
1. Read the OTC (see "Reading the OTC").
2. Erase the OTC memory (see "Erasing the OTC
Memory").
3. With the shift lever in neutral, start the engine, and
let it idle.
4. The SRS indicator will come on for about 6 seconds
and then go off.
5. Shake the wire harness and the connectors, take a
test drive (quick acceleration, quick braking,
cornering), turn the steering wheel fully left and
right, and hold itthere for 5 to 10 seconds. If the
problem recurs, the SRS indicator will come on.
6. If you can't duplicate the intermittent failure, the
system is OK at this time.