Severity Filters - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

• VPN Tunnel
Controls the forwarding of an event to a VPN connection (IPsec, SINEMA RC). As long
as the event is present, the VPN connection is switched to active.
• Firewall
Controls application of the user-defined rule set. This requires a rule set to be
assigned to the digital input under "Security > Firewall > User Specific".
Procedure
Establishing/terminating a VPN tunnel via the digital input
1. For the "Digital In" event, activate the "VPN Tunnel" entry.
2. Configure the VPN connection
– IPsec:
– SINEMA RC:
3. Click on "Set Values".
4.4.6.2

Severity Filters

On this page, you configure the severity for the sending of system event notifications.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
In "Operation" set "wait on DI" or "start on DI". You can find more information on
this in "IPsec VPN > Connections" and in "VPN connection establishment".
For "Type of connection", set "Auto" or "Digital In". For "Auto" type of connection,
you must set the "Digital In" type of connection on the SINEMA RC Server under
"Remote connections > Devices". You can find additional information on this topic
in the operating instructions "SINEMA RC Server".
Configuring with Web Based Management
4.4 "System" menu
151