Basic Settings
1.3.1
View the software versions present
on the device
The dialog shows the existing software versions:
Stored Version:
The version of the software stored in the flash memory.
Running Version:
The version of the software currently running.
Backup Version:
The version of the previous software stored in the flash memory.
1.3.2
TFTP Software Update
For a tftp update you need a tftp server on which the software to be loaded
is stored.
The URL identifies the path to the software stored on the tftp server. The URL
is in the format
tftp://IP address of the tftp server/path name/file name
(e.g. tftp://192.168.1.1/device/device.bin).
Click "tftp Update" to load the software from the tftp server to the device.
To start the new software after loading, cold start the device
"Restart").
26
1.3 Software
(see on page 38
RM Web L2B
Release 5.3 05/2012