AudioCodes Mediant 800 MSBG User Manual page 691

Multi-service business gateway
Hide thumbs Also See for Mediant 800 MSBG:
Table of Contents

Advertisement

SIP User's Manual
Parameter
Registrar Parameters
Web: Enable Registration
EMS: Is Register Needed
[IsRegisterNeeded]
Web/EMS: Registrar Name
[RegistrarName]
Web: Registrar IP Address
EMS: Registrar IP
[RegistrarIP]
Version 6.2
This table parameter can include up to 32 indices (0-31).
For configuring the Proxy Set IDs and their IP addresses,
use the parameter ProxyIP.
For configuring the Proxy Set ID table using the Web
interface and for a detailed description of the parameters of
this ini file table, see ''Configuring Proxy Sets Table'' on
page 126.
For an explanation on using ini file table parameters, see
''Configuring ini File Table Parameters'' on page 368.
Enables the device to register to a Proxy/Registrar server.
[0] Disable = The device doesn't register to Proxy/Registrar
server (default).
[1] Enable = The device registers to Proxy/Registrar server
when the device is powered up and at every user-defined
interval (configured by the parameter RegistrationTime).
Note: The device sends a REGISTER request for each
channel or for the entire device (according to the
AuthenticationMode parameter).
Registrar domain name. If specified, the name is used as the
Request-URI in REGISTER messages. If it isn't specified
(default), the Registrar IP address, or Proxy name or IP
address is used instead.
The valid range is up to 49 characters.
The IP address (or FQDN) and port number (optional) of the
Registrar server. The IP address is in dotted-decimal notation,
e.g., 201.10.8.1:<5080>.
Notes:
If not specified, the REGISTER request is sent to the
primary Proxy server.
When a port number is specified, DNS NAPTR/SRV queries
aren't performed, even if the parameter DNSQueryType is
set to 1 or 2.
If the parameter RegistrarIP is set to an FQDN and is
resolved to multiple addresses, the device also provides
real-time switching (hotswap mode) between different
Registrar IP addresses (the parameter IsProxyHotSwap is
set to 1). If the first Registrar doesn't respond to the
REGISTER message, the same REGISTER message is
sent immediately to the next Proxy. To allow this
mechanism, the parameter EnableProxyKeepAlive must be
set to 0.
When a specific transport type is defined using the
parameter RegistrarTransportType, a DNS NAPTR query is
not performed even if the parameter DNSQueryType is set
to 2.
691
12. Configuration Parameters Reference
Description
February 2011

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents