P4: PLC for SINUMERIK 828D
14.6 Function interface
14.6.5.1

The ASUB UP interface

Job start
DB3400
Byte
Bit 7
DBB 0000
DBB 0001
DBB 0002
DBB 0003
INT1 start, INT2 start
1: Starts the execution of the ASUB, which is assigned to the INT in question.
0: Reset to 0 for acknowledgement input in the result interface
Job result
DB3400
Byte
Bit 7
DBB 1000
DBB 1001
DBB 1002
DBB 2003
1196
ASUB: Job [r/w]
Bit 6
Bit 5
ASUB: Result [r]
Bit 6
Bit 5
PLC -> NCK interface
Bit 4
Bit 3
PLC -> NCK interface
Bit 4
Bit 3
INT1
ASUB
Interrupt
cannot be
executed
allocated
INT2
ASUB
Interrupt
cannot be
executed
allocated
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Bit 2
Bit 1
Bit 2
Bit 1
ASUB is
No. not
being
executed
ASUB is
No. not
being
executed
Basic Functions
Bit 0
INT1 start
INT2 start
Bit 0
ASUB
completed
ASUB
completed

Advertisement