Siemens SINUMERIK 828D Function Manual page 1165

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Error in job
DB1200.DBX5000.1 = 1 job had an error, execution terminated.
DB1200.DBX5000.1 = 0 otherwise is zero, if the user resets "Start".
Possible error causes
Index of the PI service (DB1200.DBB4001) outside the valid range
Parameter error
PI services: Cycle diagram
User sets the signal "Start", job execution starts.
After the PLC firmware signals "Job completed", the user resets the signal "Start".
By resetting the signal "Start", the PLC firmware resets the signal "Job completed".
After the PLC firmware signals "Error in job", the user resets the signal "Start".
By resetting the signal "Start", the PLC firmware resets the signal "Error in job".
If the user accidentally resets the signal "Start" before one of the signals "Job completed" or
"Error in job" is received, then the result signals for this job are not updated. However, the job is
executed.
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
P4: PLC for SINUMERIK 828D
14.6 Function interface