Reference speed for path feedrate override
The reference speed for the path feedrate override specified via machine control panel can be set as different
from the standard value:
MD12082 $MN_OVR_REFERENCE_IS_MIN_FEED
Axis-specific feedrate override
For each positioning axis an enable signal and a byte for the feedrate override factor is in the NC/PLC interface.
DB31, ... DBX1.7 (override effective)
DB31, ... DBB0 (feedrate override)
The override factor can be specified from the PLC either in the binary or gray-coded format. This format being
used is communicated to the NC via the following machine data:
MD12000 $MN_OVR_AX_IS_GRAY_CODE (axis feedrate override switch gray-coded)
The following permanent assignment applies for binary code:
Binary code
00000000
00000001
00000010
00000011
00000100
...
01100100
...
11001000
For gray coding, the override factors corresponding to the switch setting should be entered into machine data:
MD12010 $MN_OVR_ FACTOR_AX_ SPEED (evaluation of axis feedrate override switch).
Effectiveness of the axis-specific feedrate override
Active in G33, G34, G35
For active G63
In active G331, G332
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Decimal
0
1
2
3
4
...
100
...
200
not functional
not active
(the override is set in the NC permanently to
100%)
not active
(the override is set in the NC permanently to
100%)
17.4 Feedrate control
Override factor
0,00 ≙ 0%
0,01 ≙ 1%
0,02 ≙ 2%
0,03 ≙ 3%
0,04 ≙ 4%
...
1,00 ≙ 100%
...
2,00 ≙ 200%
V1: Feedrates
1393