Signals To Axis/Spindle (Db31 - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

DB21, ...
DBX318.7
Overstore active
Edge evaluation: No
Signal state 1 or
The overstore function is enabled (with the channel-specific PI service "_N_OST_ON"). If the PI
edge change 0  →  1
service is denied, the signal will not change.
Signal state 0 or
The overstore function is disabled (with the channel­specific PI service "_N_OST_OFF"). If the PI
edge change 1  →  0
service is denied, the signal will not change.
19.1.8

Signals to axis/spindle (DB31, ...)

DB31, ...
DBX1.0
Drive test travel enable
Edge evaluation: No
Signal state 1 or
Safety handshake when the function generator is started by the NC.
edge change
If an axis is to be traversed without further operator intervention, using:
0  →  1
DB31, ... DBX61.0 (drive test travel request) = 1 signal,
the NC requests a travel enable signal (permissive signal) from the PLC control.
If all axis travel conditions are fulfilled, PLC acknowledges this with:
DB31, ... DBX1.0 (drive test travel enable) = 1 signal
The PLC always has the master authority in deciding whether an axis can be traversed.
Signal state 0 or
The NC does not request permission to move axis from the PLC with:
edge change
DB31, ... DBX1.0 (drive test travel enable) = 0 signal
1  →  0
Additional
/IDsl/ Commissioning Manual IBN CNC: NCK, PLC, Drive
references
DB31, ...
DBX1.3
Axis/spindle disable
Edge evaluation: No
Signal state 1 or
(Test status)
edge change 0  →  1
If the interface signal "Axis disable" is output - for this axis - no more position partial setpoints are
- Axis disable
output to the position controller; the axis travel is therefore disabled. The position control loop
remains closed and the remaining following error is reduced to zero.
- Spindle disable
If an axis is moved with axis disable the actual value position display shows the setpoint position
and the actual velocity value display shows the setpoint velocity even though the machine axis is
not actually moving.
With a RESET the position actual value display is set to the real actual value of the machine.
Travel commands continue to be output to the PLC for this axis.
If the interface signal is canceled again the associated axis can again traverse normally.
If the interface signal "Axis disable" is set for a traversing axis, the axis is stopped with a ramp stop.
If the interface signal "Spindle disable" is set, as for axis disable, for this spindle no more speed
setpoints are output to the speed controller in the open­loop control mode and no more position
partial setpoints are output to the position controller in positioning mode. The movement of the
spindle is thus disabled. The speed actual value display displays the speed setpoint value.
Spindle disable can only be canceled per "Reset" or with M2 followed by a program restart.
If interface signal "Spindle disable" is set while a spindle is turning, the spindle is stopped according
to its acceleration characteristic.
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Signal(s) updated: Cyclically
Signal(s) updated: Cyclic
Signal(s) updated: Cyclic
Z1: NC/PLC interface signals
19.1 Various interface signals and functions (A2)
1625

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents