Siemens SINUMERIK 828D Function Manual page 1629

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

DB31, ...
DBX1.5 - DBX1.6
Position measuring system 1 (PMS1) / Position measuring system 2 (PMS2)
Edge evaluation: No
PMS1:
Position measuring system 1 is used for the axis/spindle (e.g. for position control, absolute value
Signal state 1
calculation, display). If a position measuring system 2 also exists
(MD30200 $MA_NUM_ENCS = 2), this actual value is also acquired.
PMS2:
Signal state 0
PMS1:
Position measuring system 2 is used for the axis/spindle (e.g. for position control, absolute value
Signal state 0
calculation, display). If a position measuring system 1 also exists, this actual value is also acquired.
PMS2:
Signal state 1
PMS1:
As it is not possible to use both position measuring systems simultaneously for the position control
Signal state 1
of an axis/spindle, the control automatically selects position measuring system 1.
If a position measuring system 2 also exists, this actual value is also acquired.
PMS2:
Signal state 1
PMS1:
1. The axis is in the park position.
Signal state 0
PMS2:
Signal state 0
2. The spindle does not have a position measuring system and is only speed controlled.
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Signal(s) updated: Cyclic
This means that the following features are valid:
Both position measuring systems are inactive.
There is no actual value acquisition.
The position measuring system monitoring functions are disabled
(among others, cable connection of a measured value encoder).
The reference point has no effect:
DB31, ... DBX60.4/5 (referenced/synchronized) has the signal condition 0
As soon as an axis is parked, the interface signals:
DB31, ... DBX61.5 (position controller active),
DB31, ... DBX61.6 (speed controller active)
and
DB31, ... DBX61.7 (current controller active)
are set to a 0.
After parking has been completed the axis must be re-referenced (reference point
approach).
If interface signals PMS1 and PMS2 are set to 0 while the axis is moving, the axis is stopped
with a ramp stop without the controller enable being internally withdrawn.
This is appropriate for the following situations:
Spindle encoder no longer outputs a signal above a certain speed (no longer supplies any
pulses).
Spindle encoder is decoupled mechanically because it would not be able to cope with the
speed.
The spindle can then continue to run in speed­controlled mode. In order to really bring the
axis/spindle to a stop, the controller enable must always be removed additionally by the PLC.
In this case, the interface signal:
DB31, ... DBX2.1 (controller enable)
should be set to a 1 signal.