P3: Basic PLC Program for SINUMERIK 840D sl
13.13 Block descriptions
Description of formal parameters of SINUMERIK 840D sl
The table below lists all formal parameters of the RUN_UP function for the 840D sl:
Typ
Signal
e
MCPNum
I
MCP1In
I
MCP2In
MCP1Out
I
MCP2Out
MCP1StatSend
I
MCP2StatSend
MCP1StatRec
I
MCP2StatRec
MCP1BusAdr
I
MCP2BusAdr
MCP1Timeout
I
MCP2Timeout
MCP1Cycl
I
MCP2Cycl
MCPMPI
I
MCP1Stop
I
MCP2Stop
MCP1NotSend
I
MCP2NotSend
MCPSDB210
I
MCPCopyDB77
I
928
Type
Value range
INT
Up to 2
POINTER
E0.0 to E120.0
or
M0.0 to M248.0
or
DBn DBX0.0 to DBXm.0
POINTER
A0.0 to A120.0
or
M0.0 to M248.0
or
DBn DBX0.0 to DBXm.0
POINTER
A0.0 to A124.0
or
M0.0 to M252.0
or
DBn DBX0.0 to DBXm.0
POINTER
A0.0 to A124.0
or
M0.0 to M252.0
or
DBn DBX0.0 to DBXm.0
INT
1 ... 126
192 .. 223
S5time
Recommendation: 700 ms
S5time
Recommendation: 200 ms
BOOL
false
BOOL
BOOL
BOOL
false
BOOL
false
Comment
Number of active MCP
0:
No MCPs available
Start address for input signals of relevant
machine control panel
Start address for output signals of relevant
machine control panel
Currently no significance
Currently no significance
DP slave: PROFIBUS address
Ethernet MCP: DIP-Setting
Cyclic sign-of-life monitoring for machine
control panel
Relevant only for P ? ROFIBUS
Available owing to compatibility
0:
Start transfer of machine control
panel signals
1:
Stop transfer of machine control
panel signals
DP slave: Slave deactivated
0:
Send and receive operation activated
1:
Receive machine control panel
signals only
Available owing to compatibility
Available owing to compatibility
Function Manual, 09/2011, 6FC5397-0BP40-2BA0