Z1: NC/PLC interface signals
19.1 Various interface signals and functions (A2)
DB31, ...
DBX94.1
Heat sink temperature pre-warning
Application
As soon as "heatsink temperature prewarning" has been signaled, the PLC can, for example, initiate
example(s)
controlled shutdown of the drives.
Additional
/DAsl/ Diagnostics Guide
references
DB31, ...
DBX94.2
Ramp-up completed
Edge evaluation: no
Signal state 1
The PLC is signaled, that after a new speed setpoint has entered, the speed actual value has
reached the speed tolerance bandwidth:
MD1426 $MD_SPEED_DES_EQ_ACT_TOL (tolerance bandwidth for n
and has remained within this tolerance bandwidth for at least the time defined using machine data:
MD1427 $MD_SPEED_DES_EQ_ACT_DELAY (delay time n
refer to the diagram).
Even if the speed actual value leaves the tolerance band (because of speed fluctuations resulting
from changes in load) the "ramp­up completed" signal remains (1 signal).
Signal state 0
The conditions described above have not yet been fulfilled. The ramp­up has therefore not yet been
completed.
1646
Signal(s) updated: Cyclic
= n
- signal)
set
act
= n
- signal)
set
act