ASUB cannot be executed
Negative acknowledgment: (e.g. for Emergency Stop or channel reset request).
•
Interrupt No. not allocated
Negative acknowledgment: Number has still not been allocated. → Execute PI service ASUB?!
•
ASUB is being executed
ASUB in progress.
•
ASUB completed
Positive acknowledgment: ASUB successfully completed. The start signal can not be reset.
14.6.5.2
Signal flow
①
Function activated by user with a positive edge of
②
ASUB is being executed
③
The acknowledgement
executed
is withdrawn.
④
The signal to initiate the function is reset after receiving the acknowledgement from the user.
⑤
Signal change by the firmware
⑥
Not permitted! If function activation is reset prior to receipt of acknowledgment, the output
signals are not updated – without the operational sequence of the activated function being
affected.
⑦
ASUB cannot be executed
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
is signaled back.
ASUB completed
indicates the successful execution,
: Negative acknowledgement, error occurred.
Start
.
P4: PLC for SINUMERIK 828D
14.6 Function interface
ASUB is being
1197