Signals From Channel (Db21 - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

DB21, ...
DBX10.0 - DBX11.1
Activate channel­specific protection zone 1 ( ...10)
Signal state 0 or
The pre-activated, channel­specific protection zone 1 ( ...10) is de-activated by the PLC user
edge change
program.
1  →  0
The protection zone is immediately de-activated.
Only protection zones that have been activated via the PLC and have been pre-activated in the NC
part program can be de-activated.
Application
Before a synchronous spindle, for example, is moved into the working range, the relevant
example(s)
machine­related protection zone can be activated.
19.2.2

Signals from channel (DB21, ...)

DB21, ...
DBX272.0 –
Machine­related protection zone 1 ( ...10) pre-activated
DBX273.1
Edge evaluation: no
Signal state 1 or
The machine­related protection zone 1 ( ...10) is preactivated in the current block.
edge change
(Pre-activated in the part program).
0  →  1
The protection zone can therefore be activated or de-activated in the PLC user program using the
interface signal:
DB21, ... DBX8.0 - DBX9.1 (machine-related protection zone 1 (...10))
Signal state 0 or
The machine­related protection zone 1 ( ...10) is deactivated in the current block.
edge change
(De-activated in the part program).
1  →  0
The protection zone can therefore not be activated or de-activated in the PLC user program using
the interface signal:
DB21, ... DBX8.0 to DBX9.1 (activate machine-related protection zone 1 (...10))
Corresponding
DB21, ... DBX8.0 - DBX9.1 (activate machine-related protection zone 1 (...10))
to ....
DB21, ...
DBX274.0 –
Channel­specific protection zone 1 (...10) pre-activated
DBX275.1
Edge evaluation: no
Signal state 1 or
The channel­specific protection zone 1 ( ...10) is preactivated in the current block.
edge change
(Pre-activated in the part program).
0  →  1
The protection zone can therefore be activated or de-activated in the PLC user program using the
interface signal:
DB21, ... DBX10.0 - DBX11.1 channel-specific protection zone 1 (...10))
Signal state 0 or
The channel­specific protection zone 1 ( ...10) is deactivated in the current block.
edge change
(De-activated in the part program.)
1  →  0
The protection zone can therefore not be activated or de-activated in the PLC user program using
the interface signal:
DB21, ... DBX10.0 - DBX11.1 (channel-specific protection zone 1 (...10))
Corresponding
DB21, ... DBX10.0 - DBX11.1 (activate channel-specific protection zone 1 (...10))
to ....
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Signal(s) updated: cyclic
Signal(s) updated: cyclic
Z1: NC/PLC interface signals
19.2 Axis monitoring, protection zones (A3)
1653