P3: Basic PLC Program for SINUMERIK 840D sl
13.13 Block descriptions
Description of formal parameters
The table below lists all formal parameters of the ASUB function.
Typ
Signal
e
Start
I
ChanNo
I
IntNo
I
Active
A
Done
A
Error
A
StartErr
A
Ref
I/O
Timing diagram
(1)
Activation of function
(2)
ASUP active
(3)
Positive acknowledgment: ASUB ended
(4)
Reset function activation after receipt of acknowledgment
(5)
Signal change using FC
(6)
Not permitted If function activation is reset prior to receipt of acknowledgment, the output signals
are not updated without the operational sequence of the activated function being affected.
(7)
Negative acknowledgment: Error has occurred
1016
Type
Value range
BOOL
INT
1 ... 10
INT
1 ... 8
BOOL
BOOL
BOOL
BOOL
WORD
Global variable
(MW, DBW,..)
Remark
No. of the NC channel
Interrupt No.
1 = Active
1 = ASUB completed
1 = Interrupt switched off
1 = Interrupt number not assigned or
deleted
1 word per FC 9 (for internal use)
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Basic Functions