Signals From The Mode Group (Db11) - Siemens SINUMERIK 828D Function Manual

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

DB11
DBX1.7
Single block type A
Edge evaluation: No
Signal state 1 or
DB11 DBX1.7 set and DB11 DBX1.6 not set: Response across modes
edge change
0  →  1
(If DB11 DBX1.6 and DB11 DBX1.7 are set simultaneously, it is impossible to determine which
single block type is required. The control then assumes: No single block across mode groups).
Signal state 0 or
If DB11 DBX1.7 is not set and DB11 DBX1.6 is set, then it is single block type B.
edge change
(If DB11 DBX1.6 and DB11 DBX1.7 are not set, it is impossible to determine which single block type
1  →  0
is required. The control then assumes: No single block across mode groups).
Corresponding to ...
Single block type B
19.6.2

Signals from the mode group (DB11)

DB11
DBX4.0
Selected mode AUTOMATIC
Edge evaluation: No
Signal state 1 or
AUTOMATIC mode is selected by HMI.
edge change
0  →  1
Signal state 0 or
AUTOMATIC mode is not selected by HMI.
edge change
1  →  0
DB11
DBX4.1
Selected mode MDA
Edge evaluation:
Signal state 1 or
MDA mode is selected by HMI.
edge change
0  →  1
Signal state 0 or
MDA mode is not selected by HMI.
edge change
1  →  0
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Signal(s) updated:
All channels are stopped.
All channels receive a start (start key).
Channel KS stops at the end of the block (due to single-block)
Channels KA receive a STOP command. (comparable to the STOP KEY).
All channels are stopped. (deceleration phase of all KAs)
Signal(s) updated: Cyclically
Signal(s) updated: Cyclically
19.6 Mode group, channel, program operation, reset response
Z1: NC/PLC interface signals
1671

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents