DB10
DBX56.2
Acknowledge EMERGENCY STOP
Special cases,
The EMERGENCY STOP state cannot be reset using the interface signal:
errors, ......
DB21, ... DBX7.7 (reset).
Corresponding to ....
DB10 DBX56.1 (EMERGENCY STOP)
DB10 DBX106.1 (acknowledge EMERGENCY STOP)
DB11 DBX0.7 (mode group reset)
19.8.2
Signals from NC (DB10)
DB10
DBX106.1
EMERGENCY STOP active
Edge evaluation: no
Signal state 1 or
The NC is in the EMERGENCY STOP state.
edge change
0 → 1
Corresponding to ....
DB10 DBX56.1 (EMERGENCY STOP)
DB10 DBX56.2 (acknowledge EMERGENCY STOP)
19.9
PLC basic program (P3)
To describe the NC/PLC interface signals, refer to:
References:
Functions Manual, Basic Functions; PLC Basic Program (P3)
Chapter: "Signal/Data Specifications"
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Signal(s) updated: cyclic
Z1: NC/PLC interface signals
19.9 PLC basic program (P3)
1697