Gain Adjustment Of Analog Monitor Output (Fn00D) - YASKAWA SGDV series User Manual

Ac servo drives e-v series
Table of Contents

Advertisement

6 Utility Functions (Fn
6.9

Gain Adjustment of Analog Monitor Output (Fn00D)

This function is used to manually adjust the gains for the analog monitor outputs (torque reference monitor
output and motor rotating speed monitor output). The gain values are factory-set before shipping. Therefore,
the user need not usually use this function.
(1) Adjustment Example
An example of gain adjustment to the motor rotating speed monitor is shown below.
Gain-adjustment Range
Adjustment Unit
The gain adjustment range is made with a 100% output set as a center value (adjustment range: 50% to 150%).
The following is a setting example.
<Setting the Set Value to -125>
100% + (–125 × 0.4) = 50%
Therefore, the monitor output voltage is 0.5 time as high.
<Setting the Set Value to 125>
100% + (125 × 0.4) = 150%
Therefore, the monitor output voltage is 1.5 times as high.
Note: The adjustment value will not be initialized when parameter settings are initialized using Fn005.
(2) Preparation
The following condition must be met to adjust the gain of the analog monitor output.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
6-16
)
Analog monitor
output voltage
1 [V]
1000 [min
Item
Specifications
100±50%
0.4%/LSB
Gain adjustment
-1
]
Motor speed
Rotation