4.3.4 Digital Operator Displays during Testing without Motor

4.3.4

Digital Operator Displays during Testing without Motor

An asterisk (∗) is displayed before status display to indicate the test without a motor operation is in progress.
∗ B B
U n 0 0 0 =
U n 0 0 2 =
U n 0 0 8 =
U n 0 0 D =
(Example: Status of power to the servomotor is OFF)
∗RUN
∗BB
∗PT NT
∗P-OT
∗N-OT
∗HBB
Note: The test without a motor status is not displayed during alarm occurs (A.
4-30
− P R M / M O N −
0
0 0 0 0 0
0
0 0 0 0 0
0
0 0 0 0 0 0 0 0 0 0
0
0 0 0 0 0 0 0 0 0 0
Display
Power is supplied to the servomotor.
Power to the servomotor is OFF.
Forward or reverse run is prohibited.
Forward run is prohibited.
Reverse run is prohibited.
In hard-wire base block (safety) state.
Status
).