YASKAWA SGDV series User Manual page 335

Ac servo drives e-v series
Table of Contents

Advertisement

10 Appendix
10.1.2 Parameters
Parameter
Size
No.
2
Application Function Select Switch 8
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn008
2
Application Function Select Switch 9
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn009
10-6
Setting
Name
Range
0000 to 7121
Lowered Battery Voltage Alarm/Warning Selection
0
Outputs alarm (A.830) for lowered battery voltage.
1
Outputs warning (A.930) for lowered battery voltage.
Function Selection for Undervoltage
0
Does not detect undervoltage.
1
Detects warning and limits torque by host controller.
2
Detects warning and limits torque by Pn424 and Pn425. (Only in the SERVOPACK)
Warning Detection Selection
0
Detects warning.
1
Does not detect warning (except for A.971).
Reserved (Do not change.)
0000 to 0111
Reserved (Do not change.)
Current Control Method Selection
0
Current control method 1
1
Current control method 2
Speed Detection Method Selection
0
Speed detection 1
1
Speed detection 2
Reserved (Do not change.)
Factory
When
Units
Setting
Enabled
4000
After restart
0010
After restart
(cont'd)
Classi-
Reference
fication
Section
Setup
Reference
Section
4.5.3
Reference
Section
4.2.10
Reference
Section
9.2.1
Tuning
Reference
Section
5.8.3
Reference
Section
5.8.5