1 Outline
1.7
Examples of Servo System Configurations
A system configuration for a three-phase main circuit power supply voltage of 400 VAC is shown in the fol-
lowing figure.
M-II
Molded-case
circuit breaker
(MCCB)
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is
detected.
Noise filter
Used to eliminate
external noise from
the power line.
100/200 VAC
Molded-case circuit breaker
(MCCB)
Protects the motor fan by shutting
the circuit OFF when overcurrent
is detected.
∗1. Use a 24-VDC power supply with double insulation or reinforced insulation (The power supply is not included).
∗2. The DC power supply for the 24-VDC brake is not included.
Use one of the following power supplies for 90-VDC brake.
• For 200-V input voltage: LPSE-2H01-E
• For 100-V input voltage: LPDE-1H01-E
For details, refer to Large-Capacity
∗3. For details on grounding, refer to 3.10 Noise Control and Measures for Harmonic Suppression.
∗4. Before connecting an external regenerative resistor unit, refer to 3.8 Selecting and Connecting a Regenerative Resis-
tor Unit.
∗5. For details on the dynamic brake unit, refer to 3.9 Selecting and Connecting a Dynamic Brake Unit.
∗6. For connection to the option module, refer to the manual of the command option module to be connected.
1-12
Power supply
Three-phase, 400 VAC
R S T
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
DC power
supply
*1
(24 V)
Brake power
*2
supply
Used for a
servomotor
with a 90 V brake.
Magnetic contactor
Turns the brake power
supply ON and OFF.
Install a surge absorber.
Regenerative resistor
Motor fan cable
Converter
SERVOPACK
*3
DB24
DU
DV
DW
DBON
*3
Dynamic
*5
brake unit
*4
Motor main circuit cable
Σ
-V series Catalog (Manual no.: KAEP S800000 86).
Connection cable
for digital operator
Command option
module
*6
Connection cable
for personal computer
I/O signal cable
When not using the
safety function, use
the SERVOPACK
with the safety function
jumper connector
inserted.
When using the safety
function, insert a
connection cable
specifically for the
safety function.
Battery case
(when an absolute
encoder is used.)
Thermostat cable
Encoder cable
SGMVV Servomotor
Digital
operator
Personal
computer
Host
controller
Safety function
devices