Examples Of Servo System Configurations; Three-Phase 400 V - YASKAWA SGDV series User Manual

Ac servo drives e-v series
Table of Contents

Advertisement

1 Outline
1.7

Examples of Servo System Configurations

A system configuration for a three-phase main circuit power supply voltage of 400 VAC is shown in the fol-
lowing figure.
M-II
Molded-case
circuit breaker
(MCCB)
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is
detected.
Noise filter
Used to eliminate
external noise from
the power line.
100/200 VAC
Molded-case circuit breaker
(MCCB)
Protects the motor fan by shutting
the circuit OFF when overcurrent
is detected.
∗1. Use a 24-VDC power supply with double insulation or reinforced insulation (The power supply is not included).
∗2. The DC power supply for the 24-VDC brake is not included.
Use one of the following power supplies for 90-VDC brake.
• For 200-V input voltage: LPSE-2H01-E
• For 100-V input voltage: LPDE-1H01-E
For details, refer to Large-Capacity
∗3. For details on grounding, refer to 3.10 Noise Control and Measures for Harmonic Suppression.
∗4. Before connecting an external regenerative resistor unit, refer to 3.8 Selecting and Connecting a Regenerative Resis-
tor Unit.
∗5. For details on the dynamic brake unit, refer to 3.9 Selecting and Connecting a Dynamic Brake Unit.
∗6. For connection to the option module, refer to the manual of the command option module to be connected.
1-12
Power supply
Three-phase, 400 VAC
R S T
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
DC power
supply
*1
(24 V)
Brake power
*2
supply
Used for a
servomotor
with a 90 V brake.
Magnetic contactor
Turns the brake power
supply ON and OFF.
Install a surge absorber.
Regenerative resistor
Motor fan cable
Converter
SERVOPACK
*3
DB24
DU
DV
DW
DBON
*3
Dynamic
*5
brake unit
*4
Motor main circuit cable
Σ
-V series Catalog (Manual no.: KAEP S800000 86).
Connection cable
for digital operator
Command option
module
*6
Connection cable
for personal computer
I/O signal cable
When not using the
safety function, use
the SERVOPACK
with the safety function
jumper connector
inserted.
When using the safety
function, insert a
connection cable
specifically for the
safety function.
Battery case
(when an absolute
encoder is used.)
Thermostat cable
Encoder cable
SGMVV Servomotor
Digital
operator
Personal
computer
Host
controller
Safety function
devices

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-coaSgmvv

Table of Contents