Write Prohibited Setting (Fn010) - YASKAWA SGDV series User Manual

Ac servo drives e-v series
Table of Contents

Advertisement

6.12 Write Prohibited Setting (Fn010)

This function prevents changing parameters by mistake and sets restrictions on the execution of the utility
function.
Parameter changes and execution of the utility function become restricted in the following manner when Write
prohibited (P.0001) is assigned to the write prohibited setting parameter (Fn010).
• Parameters: Cannot be changed. If you attempt to change it, "NO-OP" will flash on the display and the
screen will return to the main menu.
• Utility Function: Some functions cannot be executed. (Refer to the following table.) If you attempt to exe-
cute these utility functions, "NO-OP" will flash on the display and the screen will return to the main menu.
Parameter
No.
Fn000
Alarm history display
Fn002
JOG operation
Fn003
Origin search
Fn004
Program JOG operation
Fn005
Initializing parameter settings
Fn006
Clearing alarm history
Fn008
Absolute encoder multiturn reset and encoder alarm reset
Fn00C
Offset adjustment of analog monitor output
Fn00D
Gain adjustment of analog monitor output
Automatic offset-signal adjustment of the motor current detection
Fn00E
signal
Manual offset-signal adjustment of the motor current detection
Fn00F
signal
Fn010
Write prohibited setting
Fn011
Servomotor model display
Fn012
Software version display
Multiturn limit value setting change when a multiturn limit dis-
Fn013
agreement alarm occurs
Fn014
Resetting configuration error in option modules
Fn01B
Vibration detection level initialization
Fn01E
Display of SERVOPACK and servomotor ID
Fn01F
Display of servomotor ID in feedback option module
Fn020
Origin setting
Fn030
Software reset
Fn200
Tuning-less levels setting
Fn201
Advanced autotuning
Fn202
Advanced autotuning by reference
Fn203
One-parameter tuning
Fn204
Anti-resonance control adjustment function
Fn205
Vibration suppression function
Fn206
EasyFFT
Fn207
Online vibration monitor
Function

6.12 Write Prohibited Setting (Fn010)

Write Prohibited
Reference
Setting
Section
Executable
6.2
Cannot be executed
6.3
Cannot be executed
6.4
Cannot be executed
6.5
Cannot be executed
6.6
Cannot be executed
6.7
Cannot be executed
4.5.4
Cannot be executed
6.8
Cannot be executed
6.9
Cannot be executed
6.10
Cannot be executed
6.11
6.12
Executable
6.13
Executable
6.14
Cannot be executed
4.5.7
Cannot be executed
6.15
Cannot be executed
6.16
Executable
6.17
Executable
6.18
Cannot be executed
6.19
Executable
6.20
Cannot be executed
5.2.2
Cannot be executed
5.3.2
Cannot be executed
5.4.2
Cannot be executed
5.5.2
Cannot be executed
5.6.2
Cannot be executed
5.7.2
Cannot be executed
6.21
Cannot be executed
6.22
6
6-21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-coaSgmvv

Table of Contents