Manual Offset-Signal Adjustment Of The Motor Current Detection Signal; (Fn00F); Manual Offset-Signal Adjustment Of The Motor Current Detection Signal (Fn00F) - YASKAWA SGDV series User Manual

Ac servo drives e-v series
Table of Contents

Advertisement

6.11 Manual Offset-Signal Adjustment of the Motor Current
Detection Signal (Fn00F)
Use this function only if the torque ripple is still high after the automatic offset-signal adjustment of the motor
current detection signal (Fn00E).
Note: The adjusted value is not initialized by executing the Fn005 function (Initializing Parameter Settings).
(1) Preparation
The following condition must be met to manually adjust the offset of the motor current detection signal.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• The main circuit power must be ON.
• All alarms must be cleared.
• The hardwire baseblock (HWBB) must be disabled.
(2) Operating Procedure
Use the following procedure.
Step
Display after Operation
B B
F n 0 0 F : C u r M a n u A d j
1
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
B B
M a n u a l O f f s e t − A D J
2
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 0 9
Z A D J I V =
R U N
M a n u a l O f f s e t − A D J
3
o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 0 9
Z A D J I V =
R U N
M a n u a l O f f s e t − A D J
4
o f M o t o r C u r r e n t
Z A D J I U =
Z A D J I V =
R U N
M a n u a l O f f s e t − A D J
5
o f M o t o r C u r r e n t
Z A D J I U =
Z A D J I V =

6.11 Manual Offset-Signal Adjustment of the Motor Current Detection Signal (Fn00F)

If this function is adjusted incorrectly and then executed, characteristics of the servomo-
tor performance could be affected.
Observe the following precautions when performing manual servo tuning.
• Run the servomotor at a speed of approximately 100 min
• Adjust the offset while monitoring the torque reference with the analog monitor until
the ripple of torque reference monitor's waveform is minimized.
• Adjust the phase-U and phase-V offset amounts alternately several times until these
offsets are well balanced.
Keys
− F U N C T I O N −
-
0 0 0 0 6
-
0 0 0 0 6
-
0 0 0 1 9
-
0 0 0 0 6
-
0 0 0 1 9
-
0 0 0 0 6
-1
.
Operation
Press the
Key to view the main menu for the
utility function.
Use the
or
Key to move through the list and
select Fn00F.
Press the
Key.
The display changes to the Fn00F execution display.
Turn ON the Servo ON command from the host con-
troller.
Adjust the phase-U offset.
Press the
or
Key to adjust the offset
amount.
Adjust the offset amount by 10 in the direction that
the torque ripple is reduced.
Adjustment range: -512 to +511
(ZADJIU: Offset value of phase-U current)
Adjust the phase-V offset.
Press the
Key. The cursor moves to the phase-V
side.
6
6-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-coaSgmvv

Table of Contents