Parameter
Size
No.
2
Application Function Select Switch B
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn00B
2
Application Function Select Switch C
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn00C
Setting
Name
Range
0000 to 1111
Parameter Display Selection
0
Setup parameters
1
All parameters
Alarm Gr.2 Stop Method Selection
0
Stops the motor by setting the speed reference to "0".
1
Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
Reserved (Do not change.)
Semi-closed Encoder Usage Method
0
Uses the encoder connected to the SERVOPACK.
1
Uses the encoder connected to the feedback option module.
0000 to 0111
Selection of Test without a Motor
0
Disables test without a motor.
1
Enables test without a motor.
Encoder Resolution for Test without a Motor
0
13 bits
1
20 bits
Encoder Type for Test without a Motor
0
Incremental encoder
1
Absolute encoder
Reserved (Do not change.)
Factory
When
Units
Setting
Enabled
0000
After restart
0000
After restart
10.1 List of Parameters
(cont'd)
Classi-
Reference
fication
Section
Setup
Reference
Section
2.4.1
Reference
Section
4.2.8
4.3,
Setup
4.3.1
10
10-7