Parameter
Size
No.
2
Output Signal Inverse Setting
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn512
Pn513
2
Reserved (Do not change.)
2
Input Signal Selection 6
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn515
Pn517
2
Reserved (Do not change.)
Excessive Error Level between Servomo-
Pn51B
4
tor and Load Positions
Pn51E
2
Excessive Position Error Warning Level
Setting
Name
Range
0000 to 0111
Output Signal Inversion for CN1-25 or -26 Terminal
0
Does not inverse outputs.
1
Inverses outputs.
Output Signal Inversion for CN1-27 or -28 Terminal
0
Does not inverse outputs.
1
Inverses outputs.
Output Signal Inversion for CN1-29 or -30 Terminal
0
Does not inverse outputs.
1
Inverses outputs.
Reserved (Do not change.)
0000 to
FFFF
Reserved (Do not change.)
Reserved (Do not change.)
Dynamic Brake Answer signal 1 Input Signal Mapping (/DBANS1)
0
Detects dynamic brake (DB) contactor errors when the input signal of CN1-40 is ON (closed) while
the DB is applied.
1
Detects DB contactor errors when the input signal of CN1-41 is ON (closed) while the DB is applied.
2
Detects DB contactor errors when the input signal of CN1-42 is ON (closed) while the DB is applied.
3
Detects DB contactor errors when the input signal of CN1-43 is ON (closed) while the DB is applied.
4
Detects DB contactor errors when the input signal of CN1-44 is ON (closed) while the DB is applied.
5
Detects DB contactor errors when the input signal of CN1-45 is ON (closed) while the DB is applied.
6
Detects DB contactor errors when the input signal of CN1-46 is ON (closed) while the DB is applied.
7, 8
Disables DB contactor error detection of DB answer signal 1.
9
Detects DB contactor errors when the input signal of CN1-40 is OFF (open) while the DB is applied.
A
Detects DB contactor errors when the input signal of CN1-41 is OFF (open) while the DB is applied.
B
Detects DB contactor errors when the input signal of CN1-42 is OFF (open) while the DB is applied.
C
Detects DB contactor errors when the input signal of CN1-43 is OFF (open) while the DB is applied.
D
Detects DB contactor errors when the input signal of CN1-44 is OFF (open) while the DB is applied.
E
Detects DB contactor errors when the input signal of CN1-45 is OFF (open) while the DB is applied.
F
Detects DB contactor errors when the input signal of CN1-46 is OFF (open) while the DB is applied.
Reserved (Do not change.)
0 to
1073741824
10 to 100
Factory
Units
Setting
0000
0000
8888
0000
1
reference
1000
unit
1%
100
10.1 List of Parameters
(cont'd)
When
Classi-
Reference
Enabled
fication
Section
After restart
Setup
3.4.2
After restart
Setup
Reference
Section
3.9.4
Immediately
Setup
8.3.6
Immediately
Setup
9.2.1
10
10-21