YASKAWA SGDV series User Manual page 345

Ac servo drives e-v series
Table of Contents

Advertisement

10 Appendix
10.1.2 Parameters
Parameter
Size
No.
2
Input Signal Selection 1
4th 3rd 2nd 1st
digit digit digit digit
n.
Pn50A
10-16
Setting
Name
Range
0000 to
FFF1
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
P-OT Signal Mapping (Forward run prohibited when OFF (open))
0
Forward run allowed when CN1-40 input signal is ON (closed).
1
Forward run allowed when CN1-41 input signal is ON (closed).
2
Forward run allowed when CN1-42 input signal is ON (closed).
3
Forward run allowed when CN1-43 input signal is ON (closed).
4
Forward run allowed when CN1-44 input signal is ON (closed).
5
Forward run allowed when CN1-45 input signal is ON (closed).
6
Forward run allowed when CN1-46 input signal is ON (closed).
7
Forward run prohibited.
8
Forward run allowed.
9
Forward run allowed when CN1-40 input signal is OFF (open).
A
Forward run allowed when CN1-41 input signal is OFF (open).
B
Forward run allowed when CN1-42 input signal is OFF (open).
C
Forward run allowed when CN1-43 input signal is OFF (open).
D
Forward run allowed when CN1-44 input signal is OFF (open).
E
Forward run allowed when CN1-45 input signal is OFF (open).
F
Forward run allowed when CN1-46 input signal is OFF (open).
Factory
When
Units
Setting
Enabled
2881
After restart
(cont'd)
Classi-
Reference
fication
Section
Setup
Reference
Section
4.2.3