Alarm Number:
Alarm Name
(Alarm Description)
A.8A5:
The overspeed from the external
External Encoder
encoder occurred.
Overspeed
A.8A6:
The overheat from the external
External Encoder
encoder occurred.
Overheated
A.b31:
The current detection circuit for
Current Detection
phase U is faulty.
Error 1
A.b32:
The current detection circuit for
Current Detection
phase V is faulty.
Error 2
The detection circuit for the cur-
A.b33:
rent is faulty.
Current Detection
Error 3
The servomotor main circuit
cable is disconnected.
A.bF0:
A fault occurred in the SERVO-
PACK.
System Alarm 0
A.bF1:
A fault occurred in the SERVO-
PACK.
System Alarm 1
A.bF2:
A fault occurred in the SERVO-
System Alarm 2
PACK.
:
A fault occurred in the SERVO-
A.bF3
PACK.
System Alarm 3
A.bF4:
A fault occurred in the SERVO-
PACK.
System Alarm 4
The order of phases U, V, and W
in the servomotor wiring is incor-
rect.
A.C10:
Servo Overrun
An encoder fault occurred.
Detected
(Detected when the
servomotor power is
ON.)
A fault occurred in the SERVO-
PACK or converter.
Cause
Investigative Actions
Check the maximum speed of the
external encoder.
Check for disconnection of the ser-
vomotor main circuit cable.
Check the motor wiring.
9.1 Alarm Displays
(cont'd)
Corrective Actions
Keep the external encoder below its
maximum speed.
Replace the external encoder.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Correct the servomotor wiring.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.
Confirm that the servomotor is cor-
rectly wired.
If the alarm still occurs after turning
the power OFF and then ON again,
even though the servomotor is cor-
rectly wired, the servomotor may be
faulty. Replace the servomotor.
Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK or con-
verter may be faulty. Replace the
SERVOPACK or converter.