4.4

Projection Head Module (PHM)

4.4.1 Lens Replacement

Estimated Replacement Time: 1 minute
NOTE: This projector comes shipped with the lens.

Remove Lens

1. Place the front lens cap onto the lens.
2. Remove (2) 5 mm hex screws securing the lens to the lens mount (Figure 4-1, left).
3. Loosen the yellow lens lock knob.
4. Grasp and slide the lens out of the lens mount (Figure 4-1, middle and right).
5. Place the rear lens cap back onto the lens and store in a safe location.

Install Lens

1. Remove the rear lens cap from the lens. Keep
the front lens cap on the lens.
2. Align the lens interface plate with the lens
mount. Fully insert the assembly straight into
the lens mount opening without turning. Press
using your hand to engage the magnetic lock.
Make sure the lens IS NOT inserted
NOTICE:
at an angle as this can cause damage.
3. Tighten the yellow lens lock before fastening
the security screws.
4. Fasten the security screws.
Security screws MUST be installed.
NOTICE:
5. Remove the front lens cap.
Entero RPMSP/RPMWU/RPMHD-LED01 Service Manual
020-100368-05 Rev. 1 (06-2012)
The projector is a class 2M source of visible LED radiation. Directly viewing
the LED output with certain optical instruments within a distance of 100 mm
may pose an eye hazard.
Figure 4-1 Remove Lens
Section 4: Parts and Module Replacement
4-3