Remove a Fan Module
The fan modules are hot-service components that can be replaced if there are at least
nine operating fan modules. For the location of the fan modules, see
Locations" on page
This procedure requires that you handle components that are sensitive to electrostatic
Caution -
discharge. This discharge can cause server components to fail.
1.
Locate the faulty fan module that you want to remove from the server.
See
"Rear Panel Components (Service)" on page 15
■
fan modules in the server.
See
"Determine Which Fan Module Is Faulty" on page 142
■
fan module.
2.
Determine if you can remove the fan module with the server running.
You can remove a fan module with the server running only if one fan module is faulty and if
you have a replacement fan module. If more than one fan module is faulty, you must shut down
the server.
If you can remove the fan module with the server running, go to
■
If you cannot remove the fan module with the server running, see
■
the Server" on page 53
20.
to power down the server before continuing.
Remove a Fan Module
"Fan Module
for the locations of the
to locate a faulty
Step
3.
"Removing Power From
Servicing Fan Modules
143