Servicing Power Supplies - Oracle SPARC T5-8 Service Manual

Hide thumbs Also See for SPARC T5-8:
Table of Contents

Advertisement

Servicing Power Supplies

The power supplies are hot-service components that can be replaced at any time. There are no
slot restrictions for power supplies. Any supported power supply may be installed in any of the
four power supply slots. However, in order to maintain full power redundancy, all four power
supply slots must be occupied with functioning power supplies, and all four power cords must
be plugged in.
For the location of the power supplies, see
To take full advantage of the server's power redundancy, plug the power supplies into
Note -
separate power sources wired to two separate circuits, using a 2+2 configuration.
This procedure requires that you handle components that are sensitive to electrostatic
Caution -
discharge. This discharge can cause failure of server components.
These topics describe service procedures for the power supplies in the server.
Steps
Description
1.
Understand the power supply LEDs.
1.
Determine which power supply is faulty.
2.
Replace the power supply.
3.
Verify the replacement.
Related Information
"Identifying Components"
"Detecting and Managing Faults"
"Preparing for Service"
"Component Service Task Reference" on page 23
"Returning the Server to Operation"
"Front Panel Components (Service)" on page
Links
"Power Supply LEDs" on page 134
"Determine Which Power Supply Is
Faulty" on page 134
"Remove a Power Supply" on page 135
"Install a Power Supply" on page 137
"Verify the Power Supply" on page 138
Servicing Power Supplies
14.
133

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPARC T5-8 and is the answer not in the manual?

Questions and answers