Determine Which DIMM Is Faulty (FMA)
Time
------------------- ------------------------------------ ---------------- ---------
2013-01-18/21:04:40 7040d859-5b03-4a58-8dfd-e3a80875d62f SPSUN4V-8000-CQ MAJOR
Problem Status : solved
Diag Engine : fdd 1.0
System
Manufacturer
Name
Part_Number
Serial_Number
System Component
Manufacturer
Name
Part_Number
Serial_Number
--------------------------------------------
Suspect 1 of 1
Fault class
Certainty
Affects
Status
FRU
Description: The number of correctable errors associated with this memory
Response
Impact
Action
---------------------------------------------------------------------------
Related Information
"Determine Which DIMM Is Faulty (LEDs)" on page 75
74
SPARC T5-8 Server Service Manual • November 2015
UUID
: Oracle Corporation
: SPARC T5-8
: 12345678+11+1
: xxxxxxxxxx
: Oracle Corporation
: SPARC T5-8
: 12345678-+11+1
: xxxxxxxxxx
: fault.memory.dimm-ue
: 100%
: /SYS/PM0/CM1/CMP/BOB0/CH0/D0
: faulted but still in service
Status
: faulty
Location
: /SYS/PM0/CM1/CMP/BOB0/CH0/D0
Manufacturer : Samsung
Name
: 8192MB DDR3 SDRAM DIMM
Part_Number : 07042208,M393B1K70DH0-YK0
Revision
: 04
Serial_Number : 00CE02121585C74755
Chassis
Manufacturer
: Oracle Corporation
Name
: T5 chassis
Part_Number
: abcd
Serial_Number
: dbca
module has exceeded acceptable levels.
: An attempt will be made to remove the affected memory from
service.
: The dimm may be deconfigured at system restart which would
reduce total system memory capacity.
: Use 'fmadm faulty' to provide a more detailed view of this
event. Please refer to the associated reference document at
http://support.oracle.com/msg/SPSUN4V-8000-CQ for the latest
service procedures and policies regarding this diagnosis.
msgid
Severity

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPARC T5-8 and is the answer not in the manual?

Questions and answers

Table of Contents