Determine Which Fan Module Is Faulty
Determine Which Fan Module Is Faulty
The following LEDs are lit when a fan module fault is detected:
System Service Required LEDs on the front panel and rear I/O module
■
Server Fan Fail LED on the rear I/O module
■
Service Required LED on the faulty fan module
■
1.
Determine if the System Service Required LEDs are lit on the front panel.
See
"Interpreting LEDs" on page
2.
Determine if the Server Fan Fail LED on the front panel is lit.
See
"Front Panel Controls and LEDs" on page
From the rear of the server, check the fan module LEDs to identify which fan
3.
module needs to be replaced.
See
"Fan Module LED" on page
4.
Remove the faulty fan module.
See
"Remove a Fan Module" on page
Related Information
"Remove a Fan Module" on page 143
■
"Install a Fan Module" on page 145
■
"Verify the Fan Module" on page 146
■