Xi input
OC
TA, TB, TC
Fig.6-36 set count number and specified count number provision
F5.27
Interior timer timing setting
This parameter is used to set timing time of interior timer of the inverter.The
timer is activated by exterior triggering end(triggering end selected by F5.00~F5.07),
the timer begins timing upon receiving exterior triggering signal, after it's up to
timing time one effective pulse signal of 0.5s will be outputted from relative OC end
6.7 traverse special function parameter group: F6
F6.00
traverse function selection
0: traverse function ineffective
1: traverse function effective
F6.01
traverse run mode
0: automatic jump-in mode. After start-up run at traverse preset frequency for
a period of time, then enter into traverse operation automatically.
1: terminal manual run mode. When set the multifunction terminal Xi
( Xi=X1~X5)to function 32 and it's effective, enter into traverse state; quit traverse
state if ineffective and run frequency is at traverse preset frequency.
LED 2nd bit:
0: changing amplitude. Amplitude AW varies with center frequency, for its
changing rate please see F6.02 definition.
1: fixed amplitude. Amplitude AW is determined by high limit frequency and
F6.02.
Traverse center frequency input setting channel is set by F0.00 function.
!
F6.02
traverse amplitude
changing amplitude: AW=center frequency×F6.02
fixed amplitude: AW=high limit frequency×F6.02
EDS800 series Service Manual
1
3
2
4
Range:LED 1st bit: 0, 1
Range:0.0-50.0(%)
6
5
7
Range:0.1-6000.0s
Range:0, 1
LED 2nd bit: 0, 1
93
9
8
60.0
0.0(%)
0
00