value
feedback value
F3.07
responding to
maximum specified
value
proportion gain Kp
F3.08
Integral gain Ki
F3.09
Differential gain Kd
F3.10
Sampling cycle T
F3.11
Deviation margin
F3.12
Integral separation PID
F3.13
adjusting threshold
Closed-lop preset
F3.14
frequency
Closed-loop preset
F3.15
frequency holding
time
Sleep frequency
F3.16
threshold
Revival frequency
F3.17
threshold
Sleep delay time
F3.18
Revival delay time
F3.19
Reserved
F3.20
Long-distance pressure
F3.21
meter range
Reserved
F3.22
Reserved
F3.23
Reserved
F3.24
Reserved
F3.25
Water supply supervision
F3.26
parameter display
Closed-loop adjusting
F3.27
characteristic
LED initial
F3.28
supervision parameter
selection
EDS800 series Service Manual
0.0-100.0(%)
0.000-9.999
0.000-9.999
0.000-9.999
0.01-1.00s
0.0-20.0% Relative to the percentage of set value.
0.0-100.0%
0-upper limit frequency
0.0-6000s
0.00-400.00Hz
0.00-400.00Hz
0.0-6000.0s
0.0-6000.0s
0.001-9.999Mpa
0: C-11, C-12 denote voltage value of VCI, CCI
1: C-11, C-12 denote PID specified pressure and
feedback pressure
0: Forward function
1: Reverse function
0: set frequency
1: output frequency
2: output current
3: output voltage
4: DC bus bar voltage
5: motor speed
6: heat sink temperature
7: run time
8: accumulative run time
9: input terminal status
10: output terminal status
11: analog input VCI/PID provision
41
0.1(%) 100.0(%)
0.001
0.150
0.001
0.150
0.001
0.000
0.01s
0.10s
0.1(%)
2.0(%)
0.1(%) 100.0(%)
0.01Hz
0.00Hz
0.1s
0.0s
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.1s
0.0s
0.1s
0.0s
0.001
1.000
1
0
0
1
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○