Communication
F2.16
overtime checkout time
When serial port communication fails and its continuous time exceed set value
of this function code,the inverter judge it as communication failure.
The inverter would not detect serial port communication signal, namely this
function ineffective when set value is 0.
F2.17
Local response delay time
Local response delay time represents the time within which the inverter serial
port receive and execute command from upper device and then respond to upper
device, this function is just used for setting this delay time.
F2.18
Accelerating time 2
F2.19
Decelerating time 2
F2.20
Accelerating time 3
F2.21
Decelerating time 3
F2.22
Accelerating time 4
F2.23
Decelerating time 4
F2.24
Accelerating time 5
F2.25
Decelerating time 5
F2.26
Accelerating time 6
F2.27
Decelerating time 6
F2.28
Accelerating time 7
F2.29
Decelerating time 7
Can define 3 kinds of accelerating decelerating time and can choose
accelerating decelerating time 1 ~ 7 during inverter run process by different
combination of control terminal,please see definition for function of accelerating
decelerating time terminal in F5.00~F5.07.
Accelerating decelerating time 1 is defined in F0.08 and F0.09.
note
EDS800 series Service Manual
Range:0.0-1000.0s, 0 means
communication timeout detection invalid
Range:0-200ms
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
Range:0.1-6000.0
65
0.0s
5ms
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0