RUN command
STOP command
Fig.6-23 holding mode after PLC single circle
PLC run
RUN command
STOP command
3: consecutive circle. As shown in Fig.6-24,the inverter start next circle
automatically after finishing a circle,until there is stop command.
nd
LED 2
bit:
0: start from first step. Stop during running caused by stop command, failure
or power off,after restarting the inverter will run from first step.
1: continue to run from step frequency of interruption moment. When stop
during running caused by stop command or failure,the inverter will record current
step used time automatically and enter into this step automatically after restarting,
continue to run for residual time according to defined frequency of this step, as
EDS800 series Service Manual