mm
WIPER AND WASHER SYSTEMS
8 K - 1
REMOVE
3 SCREWS
Fig. 18 Wiper Motor/Linkage
Remove/Install
(16) Reverse remaining removal procedures to com-'
plete installation.
MULTI-FUNCTION SWITCH REMOVE/INSTALL
(1) Disconnect battery negative cable.
(2) If equipped, remove tilt column lever.
(3) Remove both upper and lower shrouds from col­
umn (Fig. 19).
UPPER
SHROUD
TILT
LEVER
PANEL
BRACKET
STEERING
WHEEL
NUT
LOWER
SHROUD
J9419-17
Fig. 19 Steering Column Shrouds
Remove/Install
(4) Remove multi-function switch tamper proof
mounting screws (tamper proof torx bit Snap On
TTXR20B2 or equivalent required).
(5) Gently pull switch away from column. Loosen
connector screw. The screw will remain in the con­
nector.
(6) Remove wiring connector from multi-function
switch (Fig. 20).
STEERING
COLUMN
ASSY.
J948K-17
J918J-1
MULTI­
F U N C T I O N
SWITCH
CONNECTOR
TURN SIGNAL
SWITCH AND
LEVER
Fig. 20 Multifunction
Switch Connector
(7) Reverse removal procedures to install. Tighten
fasteners as follows:
® multi-function switch connector screw - 1.9 N-m
(17 in. lbs.)
® multi-function switch retaining screws - 1.9 N-m
(17 in. lbs.).
WASHER RESERVOIR REMOVE/INSTALL
WARNING:
DO
NOT
LOOSEN
THE
RADIATOR
DRAINCOCK WITH THE SYSTEM HOT AND P R E S ­
SURIZED. SERIOUS BURNS FROM THE COOLANT
CAN OCCUR.
WARNING: CONSTANT TENSION HOSE CLAMPS
ARE U S E D ON COOLING SYSTEM HOSES. WHEN
REMOVING OR INSTALLING THIS TYPE OF CLAMP,
ONLY USE TOOLS DESIGNED FOR
SERVICING
THIS CLAMP SUCH AS SPECIAL CLAMP TOOL
(NUMBER 6094) (FIG. 21). SNAP-ON CLAMP TOOL
(NUMBER HPC-20) MAY B E U S E D FOR L A R G E R
CLAMPS. ALWAYS WEAR SAFETY GLASSES W H E N
SERVICING CONSTANT TENSION C L A M P S .
CAUTION: A number or letter is stamped into the
tongue of constant tension clamps (Fig. 22). If re­
placement is necessary, use only an original equip­
ment clamp with a matching number or letter.
(1) Remove upper radiator hose at radiator (Fig.
23)
(2) Pull hose off of pump and drain solvent into a
clean container for re-use.
(3) Disconnect electrical leads from pump and level
sensor (if equipped).
(4) Pull reservoir up and out of radiator shroud
(Fig.
24).