Honda 954 Service Manual page 99

Table of Contents

Advertisement

OIL PRESSURE INSPECTION
Check the oil level (page 3-15).
indicator light
Warm u p the engine t o normal operating temperature
Sto'p the engine and remove the crankcase sealing
system before
bolt.
checking the
pressure.
Connect an oil pressure gauge and attachment t o the
crankcase.
TOOLS:
Oil
pressure gauge set
Oil pressure gauge attachment
Start the engine and increase the r p m t o 5,400 rpm
and read the oil pressure.
OIL PRESSURE:
490 kPa (5.0 kgf/cm*, 7 1 psi) at 5,400 rpm/
Stop the engine and remove the tools.
Apply a locking agent to the sealing bolt threads.
Install and tighten the sealing bolt t o the specified
torque.
TORQUE: 29 N - m (3.0 kgf-m, 22 Ibf-ftl
OIL STRAINER/PRESSURE RELIEF
VALVE
REMOVAL
Drain the engine oil (page
Remove the exhaust pipe (page 2-13)
Remove the oil pan flange bolts and
07506-3000001
(Equivalent
commercially
available in U.S.A.)
0751 0-MA70000
(Equivalent
commercially
available in U.S.A.)
3-15).
oil
pan.
LUBRICATION SYSTEM
I
I
OIL
GAUGE
SEALING BOLT
I
4-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbr954rr 2002

Table of Contents