FUEL SYSTEM
(Programmed Fuel Injection)
Adjust the EGCV position by loosening the No.1
adjusting cable lock nut and turning the adjusting nut.
Move the cable several times and recheck the index
line.
Hold the No.1 cable adjusting nut, then tighten the
lock nut securely.
Turn the No.2 cable lock nut and adjust the cable so
there is no free play.
Tighten the No.2 cable lock nut securely.
Remove the jumper wire from the service check con-
nector.
INTAKE VALVE CONTROL CABLE ADJUSTMENT
Turn the ignition switch t o "ON" and short the service
check connector w i t h a jumper wire (page 5-93).
Remove the air cleaner element (page
Make sure the index lines between the intake valve
shaft pulley and air guide are aligned.
If the index lines are not aligned adjust as follows.
Loosen the intake valve cable adjuster lock nut.
Turn the intake valve cable adjuster, align the intake
valve cable guide pulley index line with the index line
on the valve shaft.
At this point, turn back the cable adjuster 112 turn.
Tighten the lock nut securely.
Remove the jumper wire f r o m the service check
connector.
5-94
LOCK NUT
LOCK NUT
\
INDE X LINE
I
INTAKE VALVE CABLE ADJUSTER
ADJUSTING NUT