FUEL SYSTEM (Programmed Fuel Injection)
Check for continuity between the No.2 injector
and ground.
Connection:
-
(+)
Ground
Standard:
No
continuity
Turn the ignition switch t o "ON".
Measure the voltage between the No.2 injector
connector of the wire harness side and ground.
Connection:
-
Ground
(+)
Standard: Battery voltage
Turn the ignition switch to
Connect the No.2 injector connector.
5-30
No continuity
"OFF".
Continuity
Faulty No.2 injector
Out of range
Open or short circuit in Blackwhite wire