Figure 6-9. Solenoid Mounting Bracket With Connector And Spare Air Line - adept technology Adept Cobra i600 User Manual

Hide thumbs Also See for Adept Cobra i600:
Table of Contents

Advertisement

Figure 6-9. Solenoid Mounting Bracket with Connector and Spare Air Line

4. Cut and discard the cable ties holding the spare air line at the top of the mounting
bracket. Move the air line away to facilitate the mounting of the solenoid
manifold (see
Figure
5. Mount the solenoid manifold onto the bracket using the supplied M3 x 25 mm
screws and washers (see
6. Insert the spare air line into the air intake coupling of the solenoid manifold.
Make sure the air line is pushed in all the way and secured in place by the intake
coupling. Confirm by pulling on the air line.
NOTE: If you are installing a Solenoid Kit on a Cleanroom robot, the spare
air line is used for a different purpose in those robots. You will have to
provide a piece of 6 mm tubing to run from one of the 6 mm user air lines
at the Joint 2 cover to the air intake coupling mentioned above.
7. Plug the connector plug into the female connector jack (marked SOLND) on the
bracket.
8. Use cable ties, as needed, to secure the air line to the bracket.
Adept Cobra i600/i800 Robot User's Guide, Rev G
6-9).
Figure 6-10 on page
Installing the Robot Solenoid Kit
Spare air line
Connector for the
solenoid valves
Pem nuts to mount the
solenoid manifold
82).