Figure 6-20. Configuration Manager - Modifying Joint 2 Limits - adept technology Adept Cobra i600 User Manual

Hide thumbs Also See for Adept Cobra i600:
Table of Contents

Advertisement

3. Click Joint 2. The following screen opens to allow editing the limits:

Figure 6-20. Configuration Manager - Modifying Joint 2 Limits

4. In the Lower Limit field, enter the new value for the J2 lower limit softstop. See
for recommended softstop values.
Table 6-8
Table 6-8. Joint 2 Ranges for Adjustable Hardstops
J2 Hardstop Position 1
J2 Hardstop Position 2
J2 Hardstop Position 3
NOTE: J2 Hardstops can be installed in a number of positions, depending
on how the robot workcell needs to be configured. The positions are
spaced 30° apart.
5. In the Upper Limit field, enter the new value for the J2 upper limit softstop. See
for recommended softstop values.
Table 6-8
6. Click Apply. The Apply Changes window opens, as illustrated in
7. Select the required options for saving joint limit values to temporary or
permanent memory. For more information on saving changes, click Help
8. Click Write to apply and save the changes.
9. Once the joint limits have been changed and written to memory, the system is
ready to use with the new limits in place.
NOTE: With both adjustable hardstop plates installed, Joint 2 has a
maximum range of motion of 160°.
Adept Cobra i600/i800 Robot User's Guide, Rev G
Installing Adjustable Hardstops
Hardstop Value
±
81°
±
51°
±
21°
Recommended Joint
Limit Softstop
Lower limit: – 80°
Upper limit: + 80°
Lower limit: – 50°
Upper limit: + 50°
Lower limit: – 20°
Upper limit: + 20°
Figure
6-15.
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adept cobra i800