High Power On/Off Lamp; Remote Front Panel Or User-Supplied Replacement; Turning On The System; Verifying Installation - adept technology Adept Cobra i600 User Manual

Hide thumbs Also See for Adept Cobra i600:
Table of Contents

Advertisement

Pins 6, 14 and 5, 13 of the XFP connector provide this remote capability. Pins 5, 13 provide
power for the lamp, +5 VDC, and ground, respectively. Pins 6, 14 are inputs for
voltage-free N/O contacts from a customer-supplied momentary push button switch.

High Power On/Off Lamp

The Front Panel High Power On/Off Lamp (P/N 27400-29006) will cause a MicroV
if the lamp burns out. This error prevents High Power from being turned on. This safety
feature prevents a user from not realizing that High Power is enabled because the High
Power indicator is burned out. See the Maintenance chapter in the
for information on changing this lamp.
User's Guide

Remote Front Panel or User-Supplied Replacement

Users can mount the Front Panel remotely by using an extension cable or by wiring a
user-supplied Front Panel (control panel) to the robot using the 15-pin XFP connector. The
Front Panel contains no active components, only switches and lights. Users should be able
to adapt the Front Panel's functionality into their own Front Panel design. To
automatically control the Front Panel's signals, use relay contacts instead of switches. See
Figure 4-9 on page 53
page 50
for a summary of connections and pin numbers.
4.8

Turning On the System

Turning on the robot system for the first time is known as "commissioning the system."
You must follow the steps in this section to safely bring up your robot system. The steps
include:
• Verifying installation, to confirm all tasks have been performed correctly
• Starting up the system by turning on power for the first time
• Verifying all E-Stops in the system function correctly
• Moving each axis of the robot to confirm it moves in the proper directions

Verifying Installation

Verifying that the system is correctly installed and that all safety equipment is working
correctly is an important process. Before using the robot, make the following checks to
ensure that the robot system has been properly installed.
Adept Cobra i600/i800 Robot User's Guide, Rev G
WARNING:
To fulfill the "Single Point of Control"
requirement, do not place the Manual/Automatic and
High Power On controls in multiple locations. To put the
robot into Manual mode, the operator should remove the
key for safety purposes. The system should not be wired
so that a PLC or another operator can put the system back
into Automatic mode.
for a schematic drawing of the Front Panel and
Turning On the System
+
error
Adept SmartController
Table 4-10 on
55