Miscellaneous functions
7.3 Measuring result screens
7.3
Measuring result screens
Function
Measurement result displays will be shown automatically during measuring cycle runtime if
_CHBIT[10]=1. If _CHBIT[10]=0 (default setting), the measurement result displays are now
shown.
Depending on the setting in _CHBIT[11] and _CHBIT[18]
● the measurement result displays are automatically deselected at the end of measuring
● the measurement result displays must be acknowledged with the NC start key
● The measurement result displays are retained until the next measuring cycle call
The measuring cycles can display different measuring result screens depending on the
measuring variant:
● Calibrating tool probes
● Measuring the tool
● Calibrating workpiece probes
● Workpiece measurement
Display result displays
The result displays contain the following data:
Calibrating tool probes
● Measuring cycle and measuring variant
● Trigger values of axis directions and differences
● Probe number
● Safe area
Measuring the tool
● Measuring cycle and measuring variant
● Actual values and differences for tool offsets
● Safe area and permissible dimensional difference
● T-, D-number
Calibrating workpiece probes
● Measuring cycle and measuring variant
● Trigger values of axis directions and differences
370
cycle (_CHBIT[11]=0, _CHBIT[18]=0)
or
(_CHBIT[11]=1, _CHBIT[18]=0). In this case, the measuring cycle outputs the message:
"Please acknowledge measurement result screen with NC start"
or
(_CHBIT[11]=0, _CHBIT[18]=1).
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0
Measuring cycles