Siemens SINUMERIK 840D sl Programming Manual page 121

Measuring cycles hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Measuring variants
Measuring cycle CYCLE976 permits the following calibration variants which are specified via
parameter _MVAR.
● Calibration in hole (axes of the plane)
6
0
1
Note
When _MVAR=xx1x0x calibration is only performed in one direction. It is not possible to
determine position deviation or calculate probe ball.
Result parameters
Measuring cycle CYCLE976 returns the following values in data block GUD5 for calibration:
Parameter
_OVR [4]
_OVR [5]
_OVR [6]1)
_OVR [7]1)
_OVR [8]
_OVR [10]
_OVR [12]
_OVR [14]
_OVR [16]
_OVR [18]
_OVR [9]
_OVR [11]
Measuring cycles
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0
Digit
5
4
3
2
1
1
8
0
0
1
0
1
2
0
1
Data type
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
Measuring Cycles for Milling and Machining Centers
5.3 CYCLE976 calibrate workpiece probe
Measuring variant
Hole (for measurement in the plane), center of the hole known
Hole (for measurement in the plane), center of the hole not known
With any data in the plane (workpiece-related)
Without including probe ball in calculation
Including probe ball in calculation (for measurement in plane)
4 axis directions
1 axis direction (also specify measuring axis and axis direction)
2 axis directions (also specify measuring axis)
Without determining position deviation of probe
With determining position deviation of probe
Paraxial calibration (in the plane)
Calibration at an angle (in the plane)
Result
Actual value probe ball diameter
Difference probe ball diameter
Center point of the hole in the abscissa
Center point of the hole in the ordinate
Trigger point in minus direction, actual value, abscissa
Trigger point in plus direction, actual value, abscissa
Trigger point in minus direction, actual value, ordinate
Trigger point in plus direction, actual value, ordinate
Trigger point in minus direction, actual value, applicate
Trigger point in plus direction, actual value, applicate
Trigger point in minus direction, difference, abscissa
Trigger point in plus direction, difference, abscissa
121