Data description
9.2 Cycle data
Channel-specific data
_TP_CF=0
_MT_COMP=0
_MT_EC_R[6,5]=(0,...,0)
_MT_EC_L[6,5]=(0,...,0
_JM_I[10]=
(0,1,1,17,100,0,0,0,0,0)
_JM_B[10]=
(0,1,0,0,0,0,0,0,0,0)
_MC_MTL[3]=
(33.3,33.3,33.3)
_MC_SIMSIM=1
_MC_SIMDIFF=0
9.2.2
Data adjustment to a specific machine
For adapting the data to a specific machine, see the following:
References:
Commissioning Manual SINUMERIK 840D sl base software and HMI sl;
Book HMI sl (IM9), chapter on measuring cycles
382
Data type
Meaning
INTEGER
No tool probe manufacturer specified (type)
INTEGER
No additional offset of the measurement result display on tool measurement
with rotating spindle (CYCLE971)
REAL
User-defined array for offsetting the measurement result on tool radius
measurement and rotating spindle (CYCLE971)
REAL
User-defined array for offsetting the measurement result on tool length
measurement and rotating spindle (CYCLE971)
INTEGER
INTEGER value field for JOG measurement
no set array number for probes like in ShopMill
•
number of array for workpiece probe is 1
•
number of array for tool probe is 1
•
working plane for measurement in JOG is G17
•
active ZO number on measurement in JOG is 0 (G500)
•
BOOL
BOOL value field for JOG measurement
offset in geometry on tool measurement
•
1 measurement attempt
•
retraction from meas. point at same velocity as intermediate positioning
•
no fast measurement feed
•
INTEGER
Probe offset during sphere measuring
(only relevant in CYCLE997 for the measurement variant with "determining
the sphere diameter")
Ratio between the tracer length/pin-sphere (ball) radius ($TC_DP6)
Pre-assignment (default) for 3 measuring probes: 100/3
If this variable is not available, then the trigger values are not corrected.
[Array index]: _PRNUM-1
INTEGER
0: Skip measuring cycles during simulation
1: Run measuring cycles during simulation
REAL
Value for simulated measuring difference
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0