Data description
9.2 Cycle data
Global data
_SI[3]=("","6","")
_PROTNAME[2]
_HEADLINE[10]
_PROTFORM[6]=(60,80,
1,3,1,12),
_PROTSYM[2]=(";","#")
_PROTVAL[13]
_PMI[4]
_SP_B[20]
_TXT[100]
_DIGIT=3
_MZ_MASK[20]
=(1,0,0,0,0,0,0,0)
380
Data type
Meaning
STRING[8]
Central strings (system information)
Internal data item
•
software version of the control
•
Internal data item
•
name of main program the log is from,
STRING[32]
•
name of log file
•
STRING[80]
Strings for log header
INTEGER
Log formatting
60 lines per page
•
80 characters per line
•
first page number is 1
•
number of header lines is 3
•
number of value lines in the log is 1
•
number of characters per column is 12
•
Separator in the log is ";"
CHAR
•
Special character for identification of tolerance limits being exceeded is
•
"#"
STRING[100]
Values
0...1:
2...5:
6...12:
INTEGER
Field for internal flags for logging
INTEGER
Variable column width
STRING[12]
Field for formatted strings
INTEGER
Number of decimal places is 3
INTEGER
Setting data for measuring cycle support
generation of a direct measuring cycle call
•
without extended ZO/tool offset
•
without input field for measuring speed and measuring feed
•
without empirical values
•
without mean value calculation
•
workpiece probe is a multidirectional probe
•
Internal data item
•
cycle-internal calculation of feedrate and spindle rotation for tool
•
measurement with rotating spindle (CYCLE971)
Title line in log;
Specification of the values to be logged
two title lines
up to 4 value lines
internal fields
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0
Measuring cycles