A.4

Overview of measuring cycle parameters

Parameter definition
Illustration in the
table (cell)
The measuring cycle data are defined in the data blocks:
● GUD5.DEF
● GUD6.DEF
Overview
CYCLE961
Parameter
Type
GUD5
_CALNUM
INT
_CORA
REAL
_CPA
REAL
_CPO
REAL
_EVNUM
INT
_FA
REAL
>0
Measuring cycles
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0
Meaning
Parameter must be defined and/or the parameter's definition depends on the
measuring variant, other parameters or the machine configuration.
----
Parameter is not used in the cycle
Note
As of HMI sl software version 2.6
The GUD parameters are stored in the machine or setting data.
A correspondence/assignment list of the measuring cycle GUD parameters, GUD
modules and measuring programs used until now, compared to the new machine and
setting data, is included in appendices A1, A2 and A3.
Workpiece measurements
Specifying distances and angles
Corner
Corner
inside
outside
3 measuring points
----
----
----
----
----
----
----
----
----
----
Only included if calculated larger than internal value
A.4 Overview of measuring cycle parameters
Automatic setup of inside and outside corner
for G17: in XY plane
for G18: in ZX plane
for G19: in YZ plane
Corner
Corner
inside
outside
4 measuring points
----
----
----
----
----
----
----
----
----
----
Measurement path in mm
Specifying 4 points
Corner inside
Corner outside
----
----
----
----
----
Appendix
----
----
----
----
----