Measuring Principle And Flow Meter Design; Measuring Principle - Siemens SITRANS FC720 Operating Instructions Manual

Coriolis c
Table of Contents

Advertisement

FC7x0

Measuring principle and flow meter design

6 Measuring principle and flow meter design

6.1 Measuring principle

The measuring principle is based on the generation of Coriolis forces. For this purpose, a
driver system (E) excites the two measuring tubes (M1, M2) in their first resonance
frequency. Both pipes vibrate inversely phased, similar to a resonating tuning fork.
Q
inlet
Fig. 2: Coriolis principle
M1,M2 Measuring tubes
S1, S2 Pick-offs
F1, F2
The fluid flow through the vibrating measuring tubes generates Coriolis forces (F1, -F1
Mass flow
and F2, -F2) that produce positive or negative values for the tubes on the inflow or
outflow side. These forces are directly proportional to the mass flow and result in
deformation (torsion) of the measuring tubes.
1
Fig. 3: Coriolis forces and measuring tube deformation
1
2
3
22 / 180
S1
-F1
F1
M1
M2
A
Coriolis forces
A
E
Measuring tube mount
Fluid
Measuring tube
A5E52748387-AA, 2023/09
outlet
-F2
-A
S2
F2
E
E
Driver system
Direction of measuring tube
A
vibration
Q
Direction of fluid flow
2
A
E
F1
3
A
Rotational axis
E
F1, F2
Coriolis forces
α
Torsion angle
Measuring principle
3
F2
1