Calibrating Tool Probes - Siemens SINUMERIK 840D sl Programming Manual

Measuring cycles hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Measuring Cycles for Turning Machines
6.3 CYCLE982 tool: Measure turning and milling tools
6.3.2

Calibrating tool probes

Function
● Calibrating tool probes - machine-related
● Calibrate tool probe, workpiece-related
Transformations can be activated in workpiece-related measurement, calibration.
The requirements and procedures are as for machine-related calibration (see "Calibrate tool
probe automatically (machine-related)").
parameters
parameters
_MVAR
_MA
_PRNUM
Additional parameters _VMS, _TZL, _TSA, _FA and _NMSP also apply.
284
Measuring variant _MVAR=0 permits machine-related calibration of a tool probe with a
calibrating tool.
This variant is already described in detail section "Calibrate tool probe automatically
(machine-related)".
Measuring variant _MVAR=10 permits
calibration of a tool probe relative to the
calibration tool relative to the workpiece.
The switching positions of the tool probe
refer to the workpiece zero. The data field
for the tool probe _PRNUM is used:
_TPW[PRNUM-1,...].
Value/data type
0
10000000
10
10000010
1, 2
INTEGER
Description
Calibrate tool probe (machine-related) with calibration tool
Calibrate tool probe (machine-related) with turning tool
Calibrate tool probe (workpiece-related) with calibration tool
Calibrate tool probe (workpiece-related) with turning tool
Measuring axis
Probe number