Siemens SINUMERIK 840D sl Programming Manual page 227

Measuring cycles hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Parameter
_RF
_KNUM
_STA1
_INCA
_TNVL
1) for measuring variant _MVAR=x1x1x9, only, measure 3 spheres
The following additional parameters are also valid:
_FA, _TSA, _VMS, _PRNUM and _NMSP
See also
Measurement path: _FA (Page 78)
Tolerance parameters: _TZL, _TMV, _TUL, _TLL, _TDIF and _TSA (Page 77)
Variable measuring velocity: _VMS (Page 76)
Probe type, probe number: _PRNUM (Page 79)
Multiple measurement at the same location: _NMSP (Page 81)
Measuring cycles
Programming Manual, 03/2009 Edition, 6FC5398-4BP10-2BA0
5.9 CYCLE997 workpiece: Measuring a sphere and ZO determination
Data type
Meaning
REAL
Velocity for intermediate paths on circular path (G2 or G3)
(for _MVAR=xx11x9, – "Measuring at an angle" only)
0, >0
0: without automatic ZO compensation
>0: with automatic ZO compensation
(Individual values: see Parameter description section "Description of
the most important defining parameters"., Parameter _KNUM)
REAL
Starting angle (for _MVAR=xx11x9, – "Measuring at an angle" only)
REAL
Stepping angle (for _MVAR=xx11x9, – "Measuring at an angle" only)
REAL
Limit value for distortion of triangle (sum of deviations)
ZO is only corrected if the calculated distortion is below this limit
value.
(for _MVAR=x1x1x9 – "Measuring 3 spheres" and _KNUM>0 only)
Measuring Cycles for Milling and Machining Centers